INSTALLATION ANd OPERATION INSTRUCTIONS
CUSTOm PASS-ThRU bACk bAR CAbINET — SELf CONTAINEd ANd REmOTE
mOdEL NOS.
PS Series
Pr Series
PS Series
PR Series
ImPORTANT INfORmATION
Table of Contents
Fill out the enclosed warranty card and mail to the
PreParing the Cabinet
Perlick Corporation to register the warranty. if the
card is not returned, the warranty period will begin
from the date the equipment is shipped from the
factory.
Specifications .....................................................2,3
List of included Parts.............................................4
tools required ......................................................4
Plumbing................................................................4
electrical................................................................4
Uncrating and inspection.......................................4
Placing the Cabinet ...............................................4
Leveling the Cabinet..............................................4
installing Legs ......................................................4
installing the base Plate........................................4
electrical Condensate evapaway Kit ....................4
refrigeration and temperature Control.................5
Cleaning the Cabinet.............................................5
Cleaning Stainless Steel .......................................5
replacement Parts................................................6
reversing Door hinge...........................................7
Wiring Diagram......................................................8
this manual has been prepared to assist you in the
installation of your Cabinet and to acquaint you with
its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. if service is required, your dealer can
provide you with a list of qualified service agents. For
your own protection, never return merchandise for
credit without our approval.
We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction.
WARNING: When lifting, the full weight of the
cabinet must be supported. Lift from the cabinet
base and not from the top. Improper lifting can
result in severe damage to the cabinet.
8300 West good hope road • Milwaukee, Wi 53223 • Phone 414-353-7060 • Fax 414-353-7069
toll Free 800-558-5592 • e-Mail: Perlick@Perlick.com • www.Perlick.com
Form no. Z2279
rev 08.01.07
installation and Operating instructions
Sizes and Specifications, Custom Pass-thru Cabinets – remote
mOdEL NOS.
nUMber OF DOOrS
PR48
2 Door
PR72
3 Door
Cabinet
DiMenSiOnS
(mm)
Length
Depth
height
48” (1219)
263/4” (679)
341/2” (876)
12.9
72” (1829)
263/4” (679)
341/2” (876)
20.4
CaSe CaPaCitY (based on 12oz. export bottle)
aMPS
.9
.9
btU/hr
2060
2500
Ship Wt. Lbs. (kg.)
310 (141)
400 (181)
interiOr
door sill: high strength polyethylene. door pan and ceiling: high strength polystyrene. floor pan and
Walls: Stainless steel. includes pilasters, (2) vinyl coated shelves and floor rack per door, and interior lights.
Front, back, top and sides stainless steel. bottom galvanized steel.
exteriOr:
DOOr hinging
Stainless steel hinges with standard locations as illustrated. For special hinging specify
hinge locations starting from left to right. Field reversible.
DOOr harDWare
reFrigeratiOn
eLeCtriCaL
door handles: black vinyl with chrome ends. Lock finish: chrome
aluminum fin and copper tube evaporator, epoxy coated coil.
115V, 60hz., 1 phase aC. Contact Perlick for other voltage/ frequency requirements.
Cabinet comes with 4 feet of 1/2” vinyl tubing for evaporator drain. the tubing exits from the center bottom of
the cabinet thru a 15/16” Dia. hole in back of the mullion.
PLUMbing
inSULatiOn
Foamed-in-place polyurethane, 2” walls, 11/2” top.
OPtiOnaL
aCCeSSOrieS &
MODiFiCatiOnS
• Leg set
• Laminated ends
door finishes
• tapping kit - 3 door only • brass hardware
• Laminated top
black vinyl coated
• base plates
Stainless steel
• Condensate evapaway kit
Customers choice of laminate
Prepared for field lamination
glass door with black vinyl coated frame
glass door with stainless steel frame
glass door with laminated frame
72” [1829] 3 DOOR
48” [1219] 2 DOOR
68” [1727] 3 DOOR
44” [1118] 2 DOOR
26 3/4”
[679]
ACCESS RIGHT
15 7/8”
[403]
OR LEFT
6 1/2”
[146]
REFRIGERATION &
ELECTRICAL ACCESS
R23 1/2”
6 3/8”
[163]
23 1/2”
[597]
6 9/16” [167]
27 7/16”
[697]
DOOR
OPENING
TYP.
7 1/2”
[191]
34 1/2”
[876]
31 1/8”
18 3/4” [476]
DOOR SILL
TO
DOOR
31 1/4”
[794]
HGT. TYP.
DOOR SILL
24” [610]
4 1/8” [105]
19 7/8”
[505]
23 1/2”
[597]
DOOR
22 3/4”
[578]
OPENING
R23 1/2”
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
3
Preparing the Cabinet for Use – Pass-thru back bar Cabinets
Parts List
Installing Legs (Optional)
■
(2) Shelves plus (1) Floor rack-per door.
Shelf Clips.
attach four legs to the cabinet bottom. Use the
supplied 1/4”- 20 x 3/4” hex head self-tapping
machine screws.
■
Suggested Tools
Placing the Cabinet
■
#2 Phillips Screwdriver.
■
10” Crescent Wrench.
Position the cabinet into place using rollers when
necessary. Important: Proper air flow around the
condensing unit is necessary for efficient operation.
never obstruct the air flow in and out of the
condensing unit.
9/16” allen Wrench.
■
5/16” and 3/8” hex Socket.
■
■
Power Drill or Driver.
Plumbing
Leveling the Cabinet
before operating the cabinet, the condensate drain
tube (furnished) must be connected. One end is
attached to the barbed elbow on the evaporator
condensate pan. the other end is inserted through
evaporator drain hole and exits the bottom of the
cabinet. the drain hole is located in the cabinet floor
pan, behind the vertical door mullion.
the drain tube must be placed over a floor drain or
into a condensate management system such as a
“COnDenSate eVaPaWaY” pan and heater.
When the cabinet is in place, check installation with
carpenter’s level. When level front to back and left
to right, accumulated water will drain out of cabinet
evaporator drain.
Electric Condensate Evapaway kit (Optional)
a 115-volt electric condensate pan can be installed
underneath the cabinet to collect and evaporate the
condensate from the cabinet evaporator. a 6 foot - 3
prong plug is included. a separate circuit should be
provided for the heater. the kit can be used only on
cabinets with 4” minimum legs. it can not be used
with platform or baseplate kits..
Electrical
the cabinet must be connected to a separately
fused power source (see electrical specification
plate) and grounded in accordance with national
and Local electrical Codes. Caution: Do not
attempt to operate the equipment on any other
power source than that listed on the electrical
Specification plate.
Installing base Plate (Optional)
attach brackets to cabinet bottom in holes pro-
vided. attach base plate to brackets. (See separate
instructions, provided with kit). When returning
cabinet to upright position, be careful not to bend
brackets.
Uncrating and Inspection
remove all crating material before operating.
Carefully inspect cabinet for hidden damage. if
damage is discovered, file your claim immediately
with the transportation company. Perlick is
not responsible for damage in transit.
WARNING! — Self Contained Units
To avoid compressor damage,after returning
cabinet to an upright position, let unit stand for
24 hours before plugging it in and running the unit.
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
4
general information
the condenser fan motor turns off and on with
the compressor. the evaporator fan motor is on
all the time.
Refrigeration and Temperature Control
the cabinet is equipped with a heavy-duty
refrigeration system designed to automatically
maintain a storage temperature of 36-41 degrees F.
the control is factory set at 38 degrees F.
NOTE:
Cabinet temperatures lower than 34° will not
allow for proper defrosting of the evaporator coil. if
defrosting is necessary, turn the control knob to the
OFF position until coil is defrosted.
4
5
3
Cleaning the Cabinet
2
6
Use a mild detergent and water to clean the inside
and outside of the cabinet. Dry thoroughly. never
use a scouring pad or abrasive cleanser.
NOTE: an industrial strength, commercial cleaner
can be used to clean the outside of painted
cabinets.
1
COLD
OFF
Adjusting the temperature
Cleaning the Condenser
the temperature control is inside the cabinet on
the left-hand side of the evaporator fan panel
assembly. You will need a screwdriver to turn the
adjusting screw. Make small adjustments until the
desired temperature is achieved.
Use a long handled, stiff brush to clean the dirt
from the front surface of the condenser. Keeping
the condenser free from dust and dirt will ensure
efficient operation.
CAUTION: Do not bend the fins while brushing the
front of the condenser.
■
Colder Temperatures:
turn the adjusting screw clockwise (to the right).
Warmer Temperatures:
■
Condenser
turn the adjusting screw counterclockwise
the condenser (located behind the front grille
cover) should be inspected every 30 days and
cleaned, if necessary.
(to the left).
Temperature Control “Off”:
turn the adjusting screw completely counter-
clockwise to the “O” position until a click is
noted.
■
Failure to keep the condenser clean will cause a
loss in condensing unit efficiency.
Recommended Cleaning Agents
JOb
CLEANING AGENT*
COmmENTS
routine Cleaning
Soap, ammonia, detergent
apply with sponge or cloth.
Can be used on all finishes.
Fingerprints and smears
areal 20, Lac-O-nu, Lumin Wash,
Provides barrier film to minimize
O’Cedar Cream Polish
fingerprints. Can be used on all finishes.
Stubborn stains and
Discolorations
allchem Concentrated Cleaner,
Samae, twinkle, Zud restoro,
rub lightly, using dry or damp
cloth in the direction of polish
lines on the stainless steel.
grade F or FFF italian Pumice,
Whiting or talc, Liquid nu Steel,
Copper’s or revere Stainless Steel
Cleaner, Lumin Cleaner, Sta-Clean,
Cameo Copper Cleaner, allen Polish
highlite, Penny-brite, Copper brite
* Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.Omission of
any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on
the package. nOte: Do not Use Steel Wool or Scouring Pads to clean stainless steel.
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
5
replacement Parts — Pass-thru back bar Cabinets
mOdEL NOS.
PS60
PR48
PS84
PR72
Condensing Units (PS Only)
Condensing unit 115 volt, 60 hz.
C22647
515301063
513200314
215315009
15352019
C22646
515301062
513200003
215315009
15352019
Condensing unit
Compressor
Fan motor assembly
Condenser coil
terminal board
Overload protector
relay
219101538
Mrt20agK5590
213516191
13556529
219101538
Mrt22aFZ5590
213516051
13556539
Capacitor
Evaproator Assembly
Self Contained (PS) complete
remote (PR) complete
evaporator coil
66071aeP
66073aeP
C17511-1eP
66072aeP
66074aeP
C17511-2eP
Fan blade
Fan motor
evaporator fan guard
temperature control
bulb clamp
57699
C15239a
65557
61283
C6634
57699
C15239a
65557
61283
C6634
Wire harness, compressor bottom
Wire harness, evaporator
Wire harness, light jumper
Light bulb
65560
65561
65051a
C15046
65560
65561
65051a
C15046
Light bulb guard
Light socket
65099-1
63484
65099-1
63484
Light switch
63303
63303
Lock
63762
63762
Space, lock
63761-1
63761-1
Lock rail
grille rail
Condenser pan
Condenser end panel
grille, black
grille, SS
Condenser housing back
Door sill
65432-24SS or 65432-24
65432-12SS or 65432-12
65565-1
65432-24SS or 65432-24
65432-12SS or 65432-12
65565-1
66215-1SS
66210-12
66210-12SS
65435-12SS
65500-1
66215-1SS
66210-12SS
66210-12
65435-12SS
65500-1
Door handle bracket
Door handle
Door gasket
65189-1
C31409-1
66237-4
65189-1
C31409-1
66237-4
Cabinet hinge
Cabinet hinge
hinge pin
65436-Lbrt
65436-Ltrb
63679-1
65436-Lbrt
65436-Ltrb
63679-1
hinge assembly, cabinet left side
hinge assembly, cabinet right side
end shelf kit
65505L
65505r
57928
65505L
65505r
57928
Center shelf kit
Left or right shelf
Center shelf
—
62307-2
57929
62307-2
62308-2
—
Vertical partition
Pilaster strip
Shelf clip
61830-1
C19271-1
C15875
61830-1
C19271-1
C15875
replacement door
rD-nL2
rD-nL2
*
Contact Perlick Milwaukee for complete door replacement. Cabinet serial no. required.
*
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
6
reversing Door hinge
STEP 9:
re-insert top hinge pin.
Tools Required
■
Phillips Screwdriver.
#4 allen Wrench.
■
STEP 10:
re-assemble lock rail from
SteP #3
■
Flathead Screwdriver or Putty Knife
Bottom Hinge Bracket Top Hinge Bracket
Operations to Perform on door
Right hinged door
(as shipped from factory)
Step #14
Operations to Perform on Cabinet
STEP 1:
remove bottom hinge pin from
assembly.
STEP 2:
Carefully lift and tilt out door
assembly from the unit and
set aside.
Step #12
Step #11
Step #13
STEP 3:
STEP 11:
remove lock rail from
cabinet, requires removal of
four screws.
remove bottom door hinge bracket from door assembly
and remove door hinge bushing from bracket.
re-assemble door hinge bracket to previous position,
without bushing.
Remove
these screws
STEP 4:
remove top hinge pin.
remove top and bottom hinge
brackets from the unit.
STEP 12:
remove top door hinge bracket from door assembly and
assemble door hinge bushing from SteP 11 to bracket.
re-assemble door hinge bracket to previous position
with bushing attached.
STEP 5:
Top Hinge Bracket Bottom Hinge Bracket
remove hinge bushing from
bottom hinge bracket and
assemble to top hinge bracket.
STEP 13:
remove handle and reposition in other set of pre-drilled
mounting holes directly underneath..
Hinge Bushing
STEP 6:
taking care not to scratch the sur-
face, remove hole plugs from the
left hinge holes.
STEP 14:
remove lock retainer and install on opposite end of
Step #7
door..
STEP 7:
insert hole plugs into vacant right
hinge holes
STEP 15:
Step #6
What was the door top is now the door bottom. Carefully
lift the door onto the hinge brackets of the cabinet. the
two hinge bushings should meet. reinsert the bottom
hinge pin to complete the door switching operation.
STEP 8:
re-assemble hinge brackets to unit. bottom right bracket
is assembled as the top left bracket. top right bracket is
assembled as the bottom left bracket.
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
7
Wiring Diagram – Custom back bar Cabinets
LIGHT SWITCH
BLACK
WHITE
PR Series Remote
2 and 3 door
WHITE
LIGHT
BLACK
LIGHT
LIGHT
LIGHT
EVAPORATOR FAN
EVAPORATOR FAN
BLACK
WHITE
THESE WIRES CAPPED IN
SINGLE CABINET
BLACK
RED
INSTALLATIONS
EVAPORATOR
NOTE:
HOUSING
FIELD WIRING FROM CABINET
GROUND WIRE
JUNCTION BOX TO CONDENSING
UNIT MUST COMPLY WITH ALL
LOCAL AND NATIONAL ELECTRICAL
CODES.
CABINET
JUNCTION BOX
CONDENSING UNIT
BLACK
WHITE
GREEN
POWER CONNECTION
JUNCTION BOX
FIELD INSTALLED
PRESSURE SWITCH
LIGHT SWITCH
BLACK
WHITE
WHITE
LIGHT
BLACK
LIGHT
LIGHT
LIGHT
PS Series Self-Contained
EVAPORATOR FAN
EVAPORATOR FAN
2 and 3 door
BLACK
WHITE
THERMOSTAT
BLACK
EVAPORATOR
HOUSING
GROUND WIRE
POWER CONNECTION
BLACK
CONDENSING UNIT
WHITE
GREEN
JUNCTION BOX
8300 West good hope road • Milwaukee, Wi 53223 • Phone 414-353-7060 • Fax 414-353-7069
toll Free 800-558-5592 • e-Mail: Perlick@Perlick.com • www.Perlick.com
Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.
Form no. Z2279
rev 08.01.07
8
|